Drillstring Buoyancy Factor Calculator in pcf, ppg and SI Units

The buoyancy factor tells you what fraction of a submerged string’s in-air weight remains as apparent weight. For a freely suspended vertical steel string with the same static fluid inside and outside, BF = 1 − fluid density/steel density. In 100 pcf fluid, using 490 pcf for steel, BF is 0.7959. A 150,000 lbf steel string therefore has a calculated apparent weight of about 119,388 lbf.

Open the buoyancy factor calculator for pcf, ppg or kg/m³.

What does a buoyancy factor of 0.7959 mean?

It means 79.59% of the in-air weight remains in this calculation. The weight reduction is the complementary fraction, 20.41%. Multiplying air weight by 0.2041 gives the reduction. Multiplying by 0.7959 gives the remaining apparent weight. Both numbers describe the same string, and interchanging them creates a large error in the expected load.

Force arrows on a static vertical steel string show downward air weight, upward fluid force and the upward support force.
For a fully submerged steel string in the stated static case, the support force plus the net upward fluid force equals the in-air string weight.

Fluid pressure increases with depth. For a flooded tubular with the same hydrostatic fluid on both sides and equal surface pressure reference, the net buoyant effect on the steel corresponds to the weight of fluid displaced by the steel volume. Fluid occupies the bore. Treating the whole cylinder enclosed by the OD as solid steel would count that bore volume as displaced as well.

Cross-section of flooded open steel tube distinguishes the annular steel material from the fluid-filled bore and surrounding fluid.
A flooded tube in the same fluid inside and outside displaces fluid equal to its steel volume. The bore remains part of the fluid domain.
Drillpipe joints stacked horizontally on racks at a Bakken location in North Dakota.
Drillpipe in the Bakken, North Dakota. The calculation starts with the air weight of the actual string tally, including the different tubulars and bottomhole components. Photo by Joshua Doubek. Source. CC BY-SA 3.0. Converted to WebP; full framing retained. Resized proportionally without enlargement. This WebP is distributed under the same licence.

Use the factor in pcf, ppg or SI units

The factor is dimensionless. Density units cancel only when fluid and steel are expressed in the same units. Use the material density for the actual component if it differs from ordinary steel. A pipe’s 19.5 lb/ft designation is linear weight; it cannot replace a material density in the formula.

Mud density entered inNominal steel reference in matching unitsFormula
lb/ft³ (pcf)490 lb/ft³BF = 1 − MWpcf/490
lb/US gal (ppg)65.5 lb/US galBF = 1 − MWppg/65.5
kg/m³7,850 kg/m³BF = 1 − ρfluid/7,850

The three steel references are independently rounded. A field sheet can use 65.4 ppg. For a comparison across units, convert the actual fluid and steel densities together and keep the ratio unrounded until the last step. For example, 100 pcf is about 13.37 ppg. Entering 100 in a ppg formula is a unit error, and rounding 0.795918 to 0.80 before multiplying would raise this example’s answer by about 612 lbf.

Unit comparison gives nominal steel density near 490 lb/ft³, 65.5 lb/US gal or 7,850 kg/m³ for the buoyancy-factor equation.
Each row uses matching units for fluid and steel. These nominal steel-density constants are independently rounded, so different rows can round to slightly different factors.

Worked example in 100 pcf mud

Start with the in-air tally of the steel suspended below the chosen reference point. For the illustrative full string, that tally is 150,000 lbf. The mud density is 100 pcf inside and outside, and the nominal steel density is 490 pcf.

BF = 1 − 100/490 = 0.795918…

Apparent string weight = 150,000 × (1 − 100/490) = 119,388 lbf, rounded

Buoyant reduction = 150,000 − 119,388 = 30,612 lbf, rounded

A scaled bar divides 150,000 lbf in-air weight into 119,388 lbf apparent weight and 30,612 lbf fluid-force reduction.
Using 490 pcf steel and carrying the full ratio before rounding gives a 119,388 lbf reference apparent weight and a 30,612 lbf reduction.

A separate way to check the arithmetic is to start with displaced volume. At standard gravity, 150,000 lbf of steel with an approximate weight density of 490 lbf/ft³ occupies about 306.12 ft³. The weight of 100 pcf fluid occupying that volume is about 30,612 lbf. Subtracting that fluid weight from the in-air tally gives the same apparent weight. This check exposes the common error of using pipe internal capacity as steel displacement.

Beam-type mud balance with its sample cup and graduated arm in an open carrying case.
A mud balance photographed for a drilling-fluid study at the University of Port Harcourt. A representative fluid-density reading supplies one input to the buoyancy factor. Photo by John Lander Ichenwo and Joel Ogbonna, Figure 4, IJERT 7(4), 2018. Source. CC BY 4.0. Original Figure 4 photograph extracted from the authors’ PDF and converted to WebP at original dimensions; full framing retained.

How much buoyed weight is below the jar?

Define the boundary first. Suppose the verified in-air weight below a jar comprises 18,000 lbf of drill collars and 12,000 lbf of other steel components. Exclude the jar itself if the tally starts at its lower connection. Under the same-fluid assumptions, the component inventory totals 30,000 lbf in air, or about 23,878 lbf buoyed in 100 pcf mud.

Component below the chosen boundaryIn-air weightApparent weight at 100 pcf
Drill collars18,000 lbf14,327 lbf
Other steel components12,000 lbf9,551 lbf
Total30,000 lbf23,878 lbf
A drillstring inventory highlights the steel components below a marked jar and applies the buoyancy factor to their combined in-air weight only.
An illustrative 30,000 lbf steel inventory below the jar has 23,878 lbf apparent weight in 100 pcf fluid on a 490 pcf steel basis. The result describes inventory weight.

Use actual component lengths and applicable assembled weights, including connections as appropriate. If a tool weight already includes internal fluid or sealed chambers, check the supplier’s weight basis before applying a steel-only correction. Where materials differ, calculate the apparent contribution for each supported component and then add them. Multiplying the whole mixed-material assembly by a generic steel factor can hide the largest source of error.

This result is an inventory below a named point. A jar’s operating load, the force transmitted to a stuck point and the surface overpull needed to fire it require different information. For a drill-collar design or target WOB, follow the separate drill-collar weight and sizing guide.

When does the simple steel factor stop being enough?

A float, plug or closed shoe can prevent the internal and annular fluid levels from equalizing. Establish what is actually inside the string and the pressure at each boundary. An empty sealed tubular and a fully flooded tubular can have identical steel weight but different suspended loads. For unlike columns or applied surface pressure, use the appropriate pressure-area and contents balance for the actual geometry, fluid levels and pressure boundaries.

Three side-by-side tubular schematics show an open flooded pipe, an empty capped pipe and different fluids in the bore and annulus.
Identify communication, fill, fluid levels and pressure at the ends before choosing a model. A float or plug alone does not determine the actual internal fluid state.

Likewise, “100 pcf mud” at the pits does not prove a uniform 100 pcf throughout the string and annulus during a displacement. A partially immersed section needs separate treatment for its immersed and unimmersed portions. For a deviated well, gravity along the trajectory and contact friction affect axial loads and surface readings. A single correction to the air tally cannot resolve these effects.

Compare predicted weight with the rig’s hookload

First line up the weight indicator’s reference with the calculation boundary. Which surface equipment is included or tared out? Was the entire string suspended off bottom and clear of the slips? Was it stationary, picking up or slacking off? Were the pumps on? A pickup reading can include upward-motion drag, and a slack-off reading can be lower. A change after the pumps start can involve hydraulic forces.

Traveling block and large hook resting on the ground beside a drilling rig in North Dakota.
Traveling block and hook laid down for maintenance in Williston, North Dakota. When comparing a calculated string weight with the rig reading, establish which suspended equipment the weight indicator includes after taring. Photo by Joshua Doubek. Source. CC BY-SA 3.0. Converted to WebP; full framing retained. Resized proportionally without enlargement. This WebP is distributed under the same licence.

The useful comparison records the in-air tally, fluid densities, fluid communication, well inclination, movement and instrument basis alongside the reading. If the discrepancy appears only while moving pipe, investigate drag before changing the assumed steel density. If it starts during displacement, reconstruct the internal and annular columns. The site’s drillstring weight guide covers the tally calculation for individual string sections.

Frequently asked questions

Does a heavier mud give a larger buoyancy factor?

For the same steel it gives a smaller factor and a larger buoyant reduction. At 120 pcf with a 490 pcf reference, BF is about 0.7551, compared with 0.7959 at 100 pcf.

Do I use nominal pipe weight or adjusted weight per foot?

Choose the unit weight that represents the actual assembly being tallied, including the intended connection allowance. Multiply by length to obtain in-air weight. Material density enters separately when calculating BF.

Does the factor change when another identical stand is added?

The factor stays the same for the same fluid, material and immersion assumptions. Adding the stand increases both in-air weight and apparent weight. If the stand is only partly immersed, apply the immersed calculation to the appropriate portion.

See the density sensitivity and hookload comparison figures
A line descends from 0.878 at 60 pcf to 0.714 at 140 pcf, with 100 pcf highlighted at 0.796 for nominal 490 pcf steel.
The plotted line applies the same-fluid steel formula across illustrative densities. It holds steel density fixed at 490 pcf.
Comparison table lists bare steel tally, surface equipment and instrument tare, drag and contact, and dynamic or hydraulic loads as separate contributors.
Compare the calculated reference with the actual instrument basis, equipment tally, motion and hydraulic state. A pickup or slack-off reading can include effects outside the static calculation.

Technical references

Baker Hughes INTEQ. Drilling Engineering Workbook: A Distributed Learning Course. Rev. B, December 1995 (80270H). Printed pp. 4-4 and 4-6–4-7 = PDF pp. 148 and 150–151.

Steve Devereux. Practical Well Planning and Drilling Manual. PennWell, copyright 1998. Printed pp. 65–69 = PDF pp. 89–93, §1.4.10. Printed pp. 69–70 = PDF pp. 93–94, §1.4.10.

Leave a Comment