The buoyancy factor tells you what fraction of a submerged string’s in-air weight remains as apparent weight. For a freely suspended vertical steel string with the same static fluid inside and outside, BF = 1 − fluid density/steel density. In 100 pcf fluid, using 490 pcf for steel, BF is 0.7959. A 150,000 lbf steel string therefore has a calculated apparent weight of about 119,388 lbf.
Open the buoyancy factor calculator for pcf, ppg or kg/m³.
What does a buoyancy factor of 0.7959 mean?
It means 79.59% of the in-air weight remains in this calculation. The weight reduction is the complementary fraction, 20.41%. Multiplying air weight by 0.2041 gives the reduction. Multiplying by 0.7959 gives the remaining apparent weight. Both numbers describe the same string, and interchanging them creates a large error in the expected load.

Fluid pressure increases with depth. For a flooded tubular with the same hydrostatic fluid on both sides and equal surface pressure reference, the net buoyant effect on the steel corresponds to the weight of fluid displaced by the steel volume. Fluid occupies the bore. Treating the whole cylinder enclosed by the OD as solid steel would count that bore volume as displaced as well.


Use the factor in pcf, ppg or SI units
The factor is dimensionless. Density units cancel only when fluid and steel are expressed in the same units. Use the material density for the actual component if it differs from ordinary steel. A pipe’s 19.5 lb/ft designation is linear weight; it cannot replace a material density in the formula.
| Mud density entered in | Nominal steel reference in matching units | Formula |
|---|---|---|
| lb/ft³ (pcf) | 490 lb/ft³ | BF = 1 − MWpcf/490 |
| lb/US gal (ppg) | 65.5 lb/US gal | BF = 1 − MWppg/65.5 |
| kg/m³ | 7,850 kg/m³ | BF = 1 − ρfluid/7,850 |
The three steel references are independently rounded. A field sheet can use 65.4 ppg. For a comparison across units, convert the actual fluid and steel densities together and keep the ratio unrounded until the last step. For example, 100 pcf is about 13.37 ppg. Entering 100 in a ppg formula is a unit error, and rounding 0.795918 to 0.80 before multiplying would raise this example’s answer by about 612 lbf.

Worked example in 100 pcf mud
Start with the in-air tally of the steel suspended below the chosen reference point. For the illustrative full string, that tally is 150,000 lbf. The mud density is 100 pcf inside and outside, and the nominal steel density is 490 pcf.
BF = 1 − 100/490 = 0.795918…
Apparent string weight = 150,000 × (1 − 100/490) = 119,388 lbf, rounded
Buoyant reduction = 150,000 − 119,388 = 30,612 lbf, rounded

A separate way to check the arithmetic is to start with displaced volume. At standard gravity, 150,000 lbf of steel with an approximate weight density of 490 lbf/ft³ occupies about 306.12 ft³. The weight of 100 pcf fluid occupying that volume is about 30,612 lbf. Subtracting that fluid weight from the in-air tally gives the same apparent weight. This check exposes the common error of using pipe internal capacity as steel displacement.

How much buoyed weight is below the jar?
Define the boundary first. Suppose the verified in-air weight below a jar comprises 18,000 lbf of drill collars and 12,000 lbf of other steel components. Exclude the jar itself if the tally starts at its lower connection. Under the same-fluid assumptions, the component inventory totals 30,000 lbf in air, or about 23,878 lbf buoyed in 100 pcf mud.
| Component below the chosen boundary | In-air weight | Apparent weight at 100 pcf |
|---|---|---|
| Drill collars | 18,000 lbf | 14,327 lbf |
| Other steel components | 12,000 lbf | 9,551 lbf |
| Total | 30,000 lbf | 23,878 lbf |

Use actual component lengths and applicable assembled weights, including connections as appropriate. If a tool weight already includes internal fluid or sealed chambers, check the supplier’s weight basis before applying a steel-only correction. Where materials differ, calculate the apparent contribution for each supported component and then add them. Multiplying the whole mixed-material assembly by a generic steel factor can hide the largest source of error.
This result is an inventory below a named point. A jar’s operating load, the force transmitted to a stuck point and the surface overpull needed to fire it require different information. For a drill-collar design or target WOB, follow the separate drill-collar weight and sizing guide.
When does the simple steel factor stop being enough?
A float, plug or closed shoe can prevent the internal and annular fluid levels from equalizing. Establish what is actually inside the string and the pressure at each boundary. An empty sealed tubular and a fully flooded tubular can have identical steel weight but different suspended loads. For unlike columns or applied surface pressure, use the appropriate pressure-area and contents balance for the actual geometry, fluid levels and pressure boundaries.

Likewise, “100 pcf mud” at the pits does not prove a uniform 100 pcf throughout the string and annulus during a displacement. A partially immersed section needs separate treatment for its immersed and unimmersed portions. For a deviated well, gravity along the trajectory and contact friction affect axial loads and surface readings. A single correction to the air tally cannot resolve these effects.
Compare predicted weight with the rig’s hookload
First line up the weight indicator’s reference with the calculation boundary. Which surface equipment is included or tared out? Was the entire string suspended off bottom and clear of the slips? Was it stationary, picking up or slacking off? Were the pumps on? A pickup reading can include upward-motion drag, and a slack-off reading can be lower. A change after the pumps start can involve hydraulic forces.

The useful comparison records the in-air tally, fluid densities, fluid communication, well inclination, movement and instrument basis alongside the reading. If the discrepancy appears only while moving pipe, investigate drag before changing the assumed steel density. If it starts during displacement, reconstruct the internal and annular columns. The site’s drillstring weight guide covers the tally calculation for individual string sections.
Frequently asked questions
Does a heavier mud give a larger buoyancy factor?
For the same steel it gives a smaller factor and a larger buoyant reduction. At 120 pcf with a 490 pcf reference, BF is about 0.7551, compared with 0.7959 at 100 pcf.
Do I use nominal pipe weight or adjusted weight per foot?
Choose the unit weight that represents the actual assembly being tallied, including the intended connection allowance. Multiply by length to obtain in-air weight. Material density enters separately when calculating BF.
Does the factor change when another identical stand is added?
The factor stays the same for the same fluid, material and immersion assumptions. Adding the stand increases both in-air weight and apparent weight. If the stand is only partly immersed, apply the immersed calculation to the appropriate portion.
See the density sensitivity and hookload comparison figures


Technical references
Baker Hughes INTEQ. Drilling Engineering Workbook: A Distributed Learning Course. Rev. B, December 1995 (80270H). Printed pp. 4-4 and 4-6–4-7 = PDF pp. 148 and 150–151.
Steve Devereux. Practical Well Planning and Drilling Manual. PennWell, copyright 1998. Printed pp. 65–69 = PDF pp. 89–93, §1.4.10. Printed pp. 69–70 = PDF pp. 93–94, §1.4.10.