A drilling mud gun circulates fluid through a nozzle to move and shear the mud in a tank. Its usefulness depends on where that fluid comes from, where the jet acts and how the receiving compartment connects to the rest of the surface system. A visible jet alone does not demonstrate that the whole compartment is mixed. [1, pp. 232–235]
This guide follows the nozzle, its supply and its effect on tank circulation. It includes an original flow-balance example and a practical equipment record. For the wider arrangement of active, reserve and treatment compartments, see the mud circulating system guide.
How a drilling mud gun moves the fluid
The pump supplies energy to the fluid. The piping carries it to the gun, and the nozzle converts part of the available pressure head into velocity. The resulting stream transfers momentum to surrounding mud and produces local circulation. The ASME handbook describes both high-pressure and low-pressure arrangements using this principle. [1, pp. 232–234]
An ordinary nozzle and an eductor are related but distinct devices. An eductor adds an inlet region through which surrounding tank fluid is drawn into the driven stream; the combined flow then leaves the mixing passage. Its discharge therefore includes both pumped fluid and entrained tank fluid. That local entrainment does not create new liquid inventory in the tank. [1, pp. 234–235]
Keep those quantities separate in a drilling mud gun assessment. Supply flow determines the load on the pump and, where fluid comes from another compartment, the added transfer. The total local circulation influenced by the jet is a different quantity. A supplier’s entrainment claim needs its stated nozzle, fluid and operating conditions before it can support a design.
For example, a supplier may describe an eductor using motive flow and total discharge. The motive flow is what the external pump provides; the difference represents fluid drawn from the surroundings. When both the inlet region and the discharge lie in the receiving tank, that difference is local recirculation. Counting total eductor discharge as external inflow would overstate the compartment balance, while counting only motive flow as all the fluid movement would underdescribe the local action. Keep the definition of each reported rate beside its value. [1, pp. 234–235]


High-pressure and low-pressure mud gun arrangements
The handbook contrasts a relatively small-flow, high-pressure system commonly supplied by a main mud pump with a larger-flow, lower-pressure arrangement commonly supplied by a centrifugal pump. Nozzle size, piping and available pump duty must be considered together. These are system descriptions, not instructions to select pressure from the name alone. [1, pp. 233–235]
For a centrifugal supply, head and pressure must also remain distinct. IADC explains that a pump at a given speed and impeller configuration is described using head; the corresponding pressure depends on the fluid density. A pressure reading from a water check therefore cannot simply be copied as the pressure expected with a different mud. [2, p. PM-2]
Neither type is automatically the best drilling mud gun for every tank. The required circulation pattern, fluid properties, available pump capacity, line arrangement and equipment ratings define the comparison. The final nozzle and supply duty belong to the selected equipment design. A catalogue pressure rating is not a recommended operating setpoint.

Trace the suction source before assessing performance
A gun may draw from the compartment it stirs, or receive fluid from a downstream compartment. ASME discusses both arrangements. Recirculating a solids-laden compartment repeatedly through a pump and nozzle can increase wear and contribute to particle degradation. Supplying cleaned fluid from farther downstream can reduce that particular burden, but it also transfers flow into the receiving compartment. [1, pp. 232–233]
The tradeoff becomes important in a removal section. A downstream supply returning upstream increases the flow that the intervening processing equipment must handle. IADC therefore distinguishes mechanical agitation from gun-fed transfer in this region and recommends considering the additional processing load. [2, p. FP-12]
For each drilling mud gun, mark the suction tank, discharge tank and intervening equipment on the actual routing sketch. Include shared pump duties and the guns expected to operate together. “The gun uses existing mud” is not a sufficient balance: the relevant question is whether that mud crosses the boundary of the compartment being assessed.

Worked example: additional flow into a treatment compartment
Consider a hypothetical compartment receiving 480 US gal/min from upstream. A gun supplied from a downstream tank adds 120 US gal/min. Assume the selected processing unit has an assessed capacity of 660 US gal/min at the stated duty. These are invented teaching values; they are not equipment specifications or a recommended design margin.
| Quantity | Illustrative value | Meaning |
|---|---|---|
| Upstream inflow | 480 US gal/min | Existing flow entering the compartment |
| External gun supply | 120 US gal/min | Additional flow crossing its boundary |
| Total inflow | 600 US gal/min | 480 + 120 |
| Assumed processing capacity | 660 US gal/min | Capacity established for this hypothetical duty |
| Capacity / total inflow | 1.10 | 660 / 600 |
Ignoring the gun would give 660/480 = 1.375, overstating the capacity relative to the actual inflow. The calculation follows the handbook’s compartment-balance reasoning. It does not measure solids-removal efficiency, separation quality or the actual fraction of particles removed. [1, pp. 236–237]
The assessment still needs the real equipment duty, bypasses, discharge routing and fluid condition. Recirculation within the same compartment has a different boundary balance even though it consumes pump capacity. Use the solids-control equipment overview to identify the relevant process, then evaluate its actual loading.

Mud gun versus mechanical agitator
A mechanical agitator uses an immersed impeller to circulate the local inventory. A drilling mud gun supplies a jet and may also transfer fluid between tanks. The ASME handbook describes combinations in which mechanical agitation supplies the main circulation and strategically placed jets address poorly swept regions. [1, pp. 237–238]
| Assessment | Mud gun | Mechanical agitator |
|---|---|---|
| Energy delivered through | Pumped fluid and nozzle | Shaft and impeller |
| Directional effect | Jet can target a particular region | Pattern depends on impeller and tank arrangement |
| Transfer between tanks | Possible when suction and discharge differ | Not provided by the impeller alone |
| Supporting assessment | Pump, nozzle, piping and routing | Drive, shaft, impeller and placement |
The comparison is about their different duties. Adding a gun does not automatically compensate for an unsuitable impeller arrangement, and a well-sized agitator does not make every corner or obstruction irrelevant. The separate mud agitator guide covers impeller and drive selection in more detail. Retain both devices on the same tank drawing so their interaction can be reviewed.


Placement: examine the tank, its corners and its internals
Tank shape, depth, fluid properties and internal obstructions influence circulation. ASME identifies right-angle compartments and poorly positioned piping as possible sources of dead regions. A gun can be directed toward such regions, but the useful reach of the jet depends on the particular arrangement and fluid. [1, pp. 226, 234–235]
For a drilling mud gun placement review, record the nozzle location and orientation, operating liquid level, tank dimensions, obstruction positions and expected solids duty. Show where the mechanical agitator discharges and where the compartment receives or loses fluid. A sketch with these features is more useful than a nozzle count without geometry.
Preserve the compartment’s process purpose. A settling compartment deliberately retains a quiet region for its intended duty; a mixing or suction compartment has a different requirement. IADC’s active-system discussion identifies the sand trap, where used, separately from the stirred compartments. Reclassifying that compartment changes the required arrangement. [2, p. FP-12]
A settled bed also deserves a separate assessment. The handbook warns that directing a gun into accumulated solids can release a concentrated slug capable of interfering with downstream equipment. Visible movement after jetting is not, on its own, evidence of satisfactory conditioning. [1, pp. 238]

Treat the nozzle and its supply as one hydraulic system
The nozzle receives only the head remaining after the supply route has consumed its share. Pipe length, diameter, bends, tees, valves and reducers therefore belong in the same calculation as nozzle size and the number of simultaneously supplied guns. ASME emphasizes these inputs when sizing lower-pressure systems. [1, pp. 235–236]
A drilling mud gun investigation should identify the pump and its actual configuration, the intended operating combination and the condition of the suction supply. Record where pressure is measured; a reading at the pump discharge is not the same as a reading at a distant nozzle inlet. Include other equipment sharing the pump, since the intended duty may differ from a single-gun check.
Avoid treating a change in one component as an isolated improvement. A larger opening changes the system duty; adding a branch changes the combined demand; rerouting a line changes resistance and possibly the receiving compartment balance. Compare the complete arrangement against the selected equipment information, rather than assuming that more indicated pressure guarantees better tank mixing.
Similarly, a pump-head comparison must use the same reference locations. The supply route consumes head before fluid reaches the nozzle, so a pump-discharge reading includes requirements that do not appear at the jet itself. Where a branch or nozzle is changed, retain the previous arrangement and the revised one in the record. That makes it possible to compare observed flow and pressure without assuming that a single gauge reading represents the whole system. [1, pp. 235–236]

Wear, inspection evidence and the handover record
The handbook identifies nozzle wear as a change that can increase flow demand and affect pump loading. It also notes wear-resistant inserts and the consequences of recirculating abrasive solids. A worn opening is therefore a hydraulic change as well as a maintenance observation. [1, pp. 233, 238]
Keep the equipment record specific enough to compare successive observations. Useful fields include gun identifier, nozzle or insert identification, measured condition, suction and receiving compartments, pump configuration, pressure location, flow evidence, tank level and concurrent duties. Attach the observation to a date and the fluid condition. This is an original record structure derived from the variables discussed in the handbook.
Do not turn every symptom into a nozzle diagnosis. Poor circulation could reflect the supply duty, route, obstruction, fluid condition or placement. A maintenance finding and a repeat performance observation should remain separately visible. Equipment examination and any pressure-containing work follow the applicable isolation and manufacturer procedures; this article is a selection and interpretation guide, not a valve-by-valve operating procedure.
The mud-system inspection and acceptance guide provides the wider rig acceptance context. For the drilling mud gun record, close the review by stating which arrangement was assessed, what changed and which evidence confirms the intended tank function.


Frequently asked questions
What is the main purpose of a drilling mud gun?
It supplies a pumped jet to create local fluid movement and shear in a mud tank. Depending on the routing, it may also transfer and blend fluid between compartments. Its performance must be judged with the tank arrangement and pump duty. [1, pp. 232–238]
Does an eductor add more liquid to the tank than its supply pump delivers?
The eductor discharge can contain pumped fluid plus fluid entrained from the same tank. That entrainment increases local movement but does not add external inventory. For a compartment balance, count only flow that crosses the chosen boundary. [1, pp. 234–235]
Can a mud gun replace all mechanical agitation?
The handbook describes practical combinations and identifies the pump and piping burden of using guns alone. Whether an arrangement can provide the required circulation depends on geometry, fluid and duty; there is no universal replacement rule. [1, pp. 237–238]
Why does the gun’s suction location matter?
It affects abrasive-solids recirculation and determines whether the gun adds flow to another compartment. A downstream supply returning upstream can increase the processing load through the intervening equipment. [1, pp. 232–233]
How many mud guns should a tank have?
The number must follow a tank and hydraulic assessment, including dimensions, obstructions, fluid properties, nozzle arrangement and available supply. A fixed count per tank volume omits these variables. [1, pp. 234–236]
Does stronger jetting prove that settled material is controlled?
No. A visible jet is a local observation. The handbook also warns that disturbing an accumulated solids bed can release a concentrated slug. Assess the fluid condition and downstream response alongside the circulation pattern. [1, pp. 238]
References
- ASME Shale Shaker Committee. Drilling Fluids Processing Handbook. Gulf Professional Publishing / Elsevier, 2005. Chapter10, Suspension, Agitation, and Mixing of Drilling Fluids. ISBN 0-7506-7775-9. Printed pages: 214,226,232–238. PDF pages in the edition consulted: 241,253,259–265.