Hydrocyclone D50: How to Read a Drilling-Mud Partition Curve

A hydrocyclone’s raw D50 is the particle size at which half the feed mass in that size class reports to the underflow. It does not say that half the total feed solids are removed. To interpret the number, identify the solids being measured, the destination stream, the sampling interval and whether the curve has been corrected for solids carried with the liquid split.

A cut point belongs to two measured streams

The cone separates a feed into overflow and underflow. Particles of one nominal size can reach either outlet. The partition curve plots size on the horizontal axis and the fraction of that size reaching a specified outlet on the vertical axis. Most drilling discussions use the underflow as the destination, but always read the axis label. A graph plotted for the overflow reverses the interpretation.

Schematic of feed entering a hydrocyclone and the separately labelled overflow and underflow outlets.
The tangential feed enters the cone. Underflow leaves near the apex and overflow exits at the top. Both products can carry liquid and solids.

Suppose a timed sample represents 10 kg/min of solids in one size class arriving at the cone and 3 kg/min of that class leaving in the underflow. The raw partition is 3/10, or 30%. The underflow sample’s own percentage in that size range cannot supply the same answer. Its size distribution needs to be multiplied by the mass flow of solids in that stream.

Vortex separator exhibit with a tall vessel and curved outlet pipes at the Houston Museum of Natural Science.
A physical hydrocyclone exhibit at the Houston Museum of Natural Science shows the vessel and outlet pipework. Its installed geometry alone cannot supply a size-partition curve. Photo: Daderot. Source. CC0 1.0. Converted to WebP. Orientation preserved. Proportionally resized to a maximum of 1,600 pixels without enlargement. Original framing and labels retained.
Class centre in a hypothetical feed10 µm20 µm30 µm40 µm60 µm
Mass of class reporting to underflow15%30%50%70%90%
Underflow recovery increases from 15 percent at 10 micrometres through 50 percent at 30 to 90 percent at 60.
In the example, half of the 30 µm feed class reports to the underflow. The other classes distribute between outlets in different proportions. The line joins illustrative class centres.

D50 is 30 µm for these illustrative measurements. Even at 60 µm, a fraction reaches the overflow. Some 10 µm material also appears in the underflow. Report the available class widths or interpolation method when the 50% crossing falls between measured points. Extra decimal places cannot restore size resolution the analysis never had.

A 20-kilogram-per-hour feed in the 30 micrometre class splits equally to overflow and underflow.
For the selected size class, 10 kg/h reports to each product and the feed contains 20 kg/h. Its underflow recovery is 10/20 or 50%.

Read the slope and the fine tail

Two cones can have the same raw D50 and different separation sharpness. A curve that rises steeply around its midpoint changes the split substantially across a narrow size interval. A broader transition distributes a wider band of sizes between both streams. For a job concerned with one damaging or valuable size range, inspect that range directly instead of ranking both cones only by their midpoint.

Hydrocyclones and connected pipes on an Evowash sand-washing plant.
Parallel hydrocyclones on a sand-washing plant show how several cones share a feed system. Sampling an individual cone and sampling a combined outlet describe different boundaries. Photo: Peter Craven. Source. CC BY 2.0. Converted to WebP. Orientation preserved. Proportionally resized to a maximum of 1,600 pixels without enlargement. Original framing and labels retained.

Part of the fine material can accompany the liquid to the underflow. Some analyses correct the measured partition for an assumed bypass fraction. For the simple constant-bypass model, corrected partition equals (raw partition − bypass)/(1 − bypass), with all terms expressed as fractions. The assumed bypass must be supported and reported. A raw 50% point and a corrected 50% point need not occur at the same diameter.

Two example curves cross at the same D50 but differ in the recovery of nearby smaller and larger particles.
The teal curve moves from low to high class recovery over a narrower size interval. The dashed curve distributes adjacent size classes more broadly, even with the same D50.

Decide what to sample on the rig

A timed balance needs representative feed, overflow and underflow samples, stream rates, solids concentrations and size distributions on a consistent basis. Link the samples to the same steady interval. A comparison that mixes different feed conditions can generate an apparent shift even when the cone remained unchanged. In weighted mud a mixed population also contains particles of different densities. A single mixed-solids curve can hide where weighting material is going.

A 10 percent liquid bypass correction changes a raw class recovery of 50 percent to a corrected 44.4 percent.
Using measured raw class recovery R and an assumed bypass b equal to the liquid split, corrected recovery is (R − b)/(1 − b). The correction depends on this model and its input measurements.
A person brushes material from a laboratory sieve toward a bowl on a balance, with stacked sieves nearby.
A laboratory worker collects material retained on a sieve for weighing. Comparable size fractions from the feed and the outlets support a particle-partition calculation. Photo: Soccer jim2002. Source. CC BY-SA 4.0. EXIF orientation normalized where present; resized proportionally to a maximum of 1600 pixels without enlargement; converted to WebP. No cropping, retouching or added labels.

Record feed conditions, including mud properties, feed pressure and the operating cones. Note the condition of the discharge and any plugging or interruptions. Size, density and fluid viscosity all influence separation. A catalogue cut point can frame a question, but it cannot establish the split achieved with the fluid and solids that passed through the cone that day.

Explore feed distribution, total recovery and closure
Contrasting denominators give 20 percent share of feed and 50 percent class recovery to underflow.
If a feed carries 20 kg/h in a selected size class out of 100 kg/h total solids and 10 kg/h in that class reaches underflow, the class represents 20% of feed and has 50% underflow recovery.
The same class partition yields 30 or 75 kilograms per hour from different 100-kilogram-per-hour feeds.
In a simplified feed containing only the 10 and 60 µm classes, the same partition curve yields 30% or 75% total recovery depending on the mix. The class recoveries are held fixed.
Example size-class balances close at 20 and 30 micrometres but leave two kilograms per hour unaccounted at 40.
A positive residual is measured feed less measured products. The illustrative 40 µm class has a 2 kg/h shortfall, so its reported recovery depends on checking the samples and rates.

Field or laboratory record

Download the editable hydrocyclone size-class balance (TXT).

Frequently asked questions

Does the median size of the underflow equal D50?

No. The median describes the distribution inside one stream. A partition cut point describes the fraction of a size class transferred between streams.

Can D50 by itself predict total removal?

Total recovery depends on how much feed material sits in each size class. Weight each class recovery by the feed mass in that class, then sum the recovered masses.

What if the balance fails to close?

Check time alignment, solids flow units, size bins and sampling of the intermittent discharge. Report the closure discrepancy alongside the result before interpreting a small change in D50.

Further reading and technical references