A hydrocyclone’s raw D50 is the particle size at which half the feed mass in that size class reports to the underflow. It does not say that half the total feed solids are removed. To interpret the number, identify the solids being measured, the destination stream, the sampling interval and whether the curve has been corrected for solids carried with the liquid split.
A cut point belongs to two measured streams
The cone separates a feed into overflow and underflow. Particles of one nominal size can reach either outlet. The partition curve plots size on the horizontal axis and the fraction of that size reaching a specified outlet on the vertical axis. Most drilling discussions use the underflow as the destination, but always read the axis label. A graph plotted for the overflow reverses the interpretation.

Suppose a timed sample represents 10 kg/min of solids in one size class arriving at the cone and 3 kg/min of that class leaving in the underflow. The raw partition is 3/10, or 30%. The underflow sample’s own percentage in that size range cannot supply the same answer. Its size distribution needs to be multiplied by the mass flow of solids in that stream.

| Class centre in a hypothetical feed | 10 µm | 20 µm | 30 µm | 40 µm | 60 µm |
|---|---|---|---|---|---|
| Mass of class reporting to underflow | 15% | 30% | 50% | 70% | 90% |

D50 is 30 µm for these illustrative measurements. Even at 60 µm, a fraction reaches the overflow. Some 10 µm material also appears in the underflow. Report the available class widths or interpolation method when the 50% crossing falls between measured points. Extra decimal places cannot restore size resolution the analysis never had.

Read the slope and the fine tail
Two cones can have the same raw D50 and different separation sharpness. A curve that rises steeply around its midpoint changes the split substantially across a narrow size interval. A broader transition distributes a wider band of sizes between both streams. For a job concerned with one damaging or valuable size range, inspect that range directly instead of ranking both cones only by their midpoint.

Part of the fine material can accompany the liquid to the underflow. Some analyses correct the measured partition for an assumed bypass fraction. For the simple constant-bypass model, corrected partition equals (raw partition − bypass)/(1 − bypass), with all terms expressed as fractions. The assumed bypass must be supported and reported. A raw 50% point and a corrected 50% point need not occur at the same diameter.

Decide what to sample on the rig
A timed balance needs representative feed, overflow and underflow samples, stream rates, solids concentrations and size distributions on a consistent basis. Link the samples to the same steady interval. A comparison that mixes different feed conditions can generate an apparent shift even when the cone remained unchanged. In weighted mud a mixed population also contains particles of different densities. A single mixed-solids curve can hide where weighting material is going.


Record feed conditions, including mud properties, feed pressure and the operating cones. Note the condition of the discharge and any plugging or interruptions. Size, density and fluid viscosity all influence separation. A catalogue cut point can frame a question, but it cannot establish the split achieved with the fluid and solids that passed through the cone that day.
Explore feed distribution, total recovery and closure



Field or laboratory record
Download the editable hydrocyclone size-class balance (TXT).
Frequently asked questions
Does the median size of the underflow equal D50?
No. The median describes the distribution inside one stream. A partition cut point describes the fraction of a size class transferred between streams.
Can D50 by itself predict total removal?
Total recovery depends on how much feed material sits in each size class. Weight each class recovery by the feed mass in that class, then sum the recovered masses.
What if the balance fails to close?
Check time alignment, solids flow units, size bins and sampling of the intermittent discharge. Report the closure discrepancy alongside the result before interpreting a small change in D50.
Further reading and technical references
For the physical cone arrangement and named outlets, see Desanders and Desilters in Oil & Gas Drilling Rigs. See Mud Cleaner in Oil & Gas Rigs for how the cone underflow can be processed on a screen.
ASME Shale Shaker Committee. Drilling Fluids Processing Handbook. Gulf Professional Publishing, 2005. Printed pp. 270–272 (PDF pp. 297–299), §11.4. Printed pp. 328–331 (PDF pp. 355–358), ch. 14.