Managed Pressure Drilling Equipment Along the Return Path

A surface-backpressure MPD package has three different jobs. It must contain returning fluid around moving drillpipe, provide a controllable restriction and measure the response. A rotating control device alone does only the first job. Walk the actual piping and instrumentation diagram from the annulus to the receiving equipment to see how the complete system performs all three.

Identify the pressure boundary

The rotating control device (RCD) seals around pipe while the return flow is diverted through an outlet. Its operating envelope depends on the sealing element, pipe geometry and movement. An allowable static pressure and an allowable differential while rotating at a stated speed are different entries in the equipment documentation. An RCD supplements the well-control stack and has a different function from a BOP.

Follow the outlet through hoses, spools and valves to the choke inlet. Mark the pressure rating, temperature basis and isolation boundary for each segment. A high rating on the manifold body cannot increase the rating of a hose or connection. Trace the paths that can exist during normal operation and during a change of return route.

The closed-loop return path. The RCD seals around moving pipe and diverts the annular return. Piping carries it to the choke and receiving system.
The RCD seals around moving pipe and diverts the annular return. Piping carries it to the choke and receiving system.

Identify the controllable restriction

A dedicated MPD choke varies restriction on fluid moving through the return path. A control system may position the choke in response to pressure measurements and a hydraulic model. Choke position, upstream pressure and downstream pressure answer different questions. A position command alone cannot demonstrate that the intended annular pressure was achieved.

Depending on system design, auxiliary flow may maintain circulation through a choke when the rig pumps slow. Show where that flow enters relative to every instrument. Where a package changes routing for gas handling, distinguish the normal measuring path from the path available in that mode. The approved piping drawing and equipment limits determine what the arrangement can do.

Trace the surface return route through the rotating head and the choke manifold. The equipment drawings identify which components contain pressure and where the pressure drop occurs.

What the rotating control device seals. The seal blocks upward escape around the pipe so annular flow can enter the return outlet.
The seal blocks upward escape around the pipe so annular flow can enter the return outlet.

Read a flow discrepancy against the drawing

Suppose a rig pump delivers an estimated 450 gpm and a separate pump supplies 30 gpm downstream of the well but upstream of a return meter. In a steady single-phase example with no storage change, the expected meter reading is 480 gpm. Comparing that meter directly with 450 gpm suggests a false 30-gpm gain. If the auxiliary tie-in is downstream of the meter, the same arithmetic would be wrong.

This example accounts for a known input. It cannot explain away an unexpected gain. During a transient, compressibility, changing line inventories, meter quality and travel time matter. Reconcile the timestamps and configuration while applying the well-specific flow-deviation criteria and independent pit measurements.

Three operating ratings to distinguish. Static, rotating and stripping service involve different motion and loading at the sealing surface.
Static, rotating and stripping service involve different motion and loading at the sealing surface.
Red pulsation dampener connected to pump piping
The dampener sits on the pump side of the circulating system. Photo by Tangythia (CC BY-SA 4.0).

Build an equipment handover that survives a shift change

Record the fitted seal element and compatible pipe range, active choke leg, instrument taps, measurement units and all flow additions counted by the meter. Distinguish the configured alarm threshold from the documented operating limit. A package acceptance test should demonstrate the behavior of the selected route, including what the operator actually sees if an expected measurement drops out.

Convert a flow mismatch into an inventory check

Duration changes the significance of a flow difference. If the displayed 30-gpm excess persists for 84 seconds, the integrated difference is 30 × 84 ÷ 60 = 42 US gallons, or 1.0 bbl. Mark the pump that supplied those gallons and the tank from which it drew. An upstream tie-in can explain the return-meter indication while a transfer between active and unmonitored tanks changes what the pit system reports.

A Coriolis meter measures mass flow and bulk density and computes volume from them. In gas-cut returns, the indicated density can drop sharply. Dividing the mass rate by that lower density produces a larger apparent volume than dividing by the density of the liquid mud. For a gain investigation, retain the raw mass-flow and density channels, the instrument diagnostics and the independent pit-volume trend alongside displayed gpm. A suspect conversion leaves the source of an unexpected gain unresolved. Casellas, Tønnessen and Olsen, Step Changes in Drilling Fluid Measurement.

Field comparison

ItemWhat it establishesWhat else must be checked
RCDPressure boundary around the moving stringSeal, pipe size, rotation and pressure envelope
ChokeAdjustable pressure drop during flowFlow supply, inlet and downstream pressure
Return meterFlow passing that particular locationAuxiliary tie-ins, bypasses and meter quality
Pit measurementNet active-system inventory changeTransfers and timing
Blowout preventer control panel in a driller’s cabin
The driller’s BOP panel is a separate control interface from the MPD choke controls. Photo by FrogsLegs71 (CC BY-SA 3.0).

What to record in the field

Check or recordJob-specific entry
RCD model, installed seal, pipe OD and documented dynamic envelope
Active route, bypass position and destination of gas-bearing returns
Auxiliary entry relative to the flow meter and pump-in channel
Controller demand, measured pressure and independent confirmation
Additional technical figures (5)
Auxiliary flow upstream of the meter. A 30 gpm addition upstream of the return meter is included in the measured flow.
A 30 gpm addition upstream of the return meter is included in the measured flow.
A normal 30 gpm apparent imbalance. With 450 gpm from the well and 30 gpm from an auxiliary line upstream of the meter, expected measured flow is 480 gpm.
With 450 gpm from the well and 30 gpm from an auxiliary line upstream of the meter, expected measured flow is 480 gpm.
Two taps define choke differential. A choke differential uses taps on opposite sides of the restriction. Choke opening alone does not measure that differential.
A choke differential uses taps on opposite sides of the restriction. Choke opening alone does not measure that differential.
A bypass changes the measurement boundary. Point measurements describe fluid crossing a specific instrument. Moving a return stream around it changes the balance.
Point measurements describe fluid crossing a specific instrument. Moving a return stream around it changes the balance.
Shift handover for the active return route. Seal, choke, flow and storage records together provide a stronger account than a single controller reading.
Seal, choke, flow and storage records together provide a stronger account than a single controller reading.

Questions from the field

Is an RCD the same as the MPD choke?

The RCD provides the seal at the top of the closed annulus. The choke establishes a variable restriction in the return line.

Can one use the static RCD rating while drilling?

Use the documented dynamic envelope for the actual pipe movement, rotation, element and fluid. A static nameplate number alone is inadequate.

Does the return meter always show well flow?

Only if the active arrangement and measurement conditions support that interpretation. Additions and bypasses can change what reaches the meter.

Mud-gas separator and shale shakers on a drilling location
A mud-gas separator and shakers occupy different positions in the returns flow path. Photo by Joshua Doubek (CC BY-SA 3.0).

Technical references

E. Tercan, Managed Pressure Drilling Techniques, Equipment & Applications. §4.1.1, printed pp. 93–96.

SPE/IADC-221433-MS, field case. Overview of Managed Pressure Drilling System, p. 3 onward.

Sanguinetti et al., MPD Well Control During Non-Drilling Operations, SPE/IADC-221436-MS. Figure 8 and its accompanying discussion illustrate the changing Coriolis flow-out signal in a simulated gas-influx case.

Leave a Comment