Two connectors can share a nominal bore and still require different ring grooves, attachment hardware or pressure ratings. Specify a wellhead adapter by describing the complete lower face, the complete upper face and the pressure-containing region between them. A request for a high-pressure flange leaves all three open to interpretation.
Define what the adapter is expected to do
An adapter spool joins unlike end connections. A spacer spool provides length between matching connections. A tubing-head adapter may also provide a seal interface for a tubing-hanger neck or penetrations for completion services. These descriptions affect the drawing you need. A plain through-bore adapter cannot automatically replace a component that forms part of the tubing-hanger seal system.
For each face record the mating equipment tag, connection designation, nominal bore, working pressure, flange or hub type, ring number and material requirements. Describe whether the face is studded or bolt-through. Separate the size of the connection from the minimum clear bore along the entire assembly. A correctly bolted adapter may still restrict the passage of a planned intervention tool.

Read different pressure regions on the section
If a simple open-bore adapter connects a 5,000-psi lower end to a 10,000-psi upper end, pressure in the open bore acts on both ends. The 10,000-psi connection alone cannot give the assembled open path a 10,000-psi working rating. Other parts or the well-specific design may set a lower allowable value still. These numbers are an illustrative comparison, not a test schedule.
A purpose-designed crossover with a qualified restricted-area sealing arrangement can separate pressure regions. Its higher rated region exists only under the arrangement prescribed for that specific assembly. Ask for a section with the seal, tubular, connector and pressure boundary identified. The stamped rating on the upper flange cannot establish whether the seal is present, correctly installed or verified.
A choke manifold and a wellhead back-pressure valve serve different pressure-control functions. Identifying the adjoining assembly helps establish which drawing and pressure envelope apply to an adapter.

Check ring groove, bolting and physical access
An API 6B flange with a type R groove takes the specified R or RX gasket. An API 6BX flange with a BX groove takes a BX gasket. RX and BX are different geometries even though both use pressure to assist sealing. Match the groove type and number marked on the connector to the specified ring number and material on the assembly drawing. The Offshore Norge flange handbook illustrates the two flange families in section 4. Stud pattern, bolt diameter, nut clearance, face separation and access for the specified tooling also matter. A ring that fits loosely into one groove has established no compatible mating geometry. Verify both faces against the controlled drawing and approved installation data.
Check the overall height against stack spacing and the smallest bore against the largest planned tool OD, including restrictions at shoulders and seals. Allow for equipment alignment and externally applied loads in the engineering assessment. An adapter can add a lever arm to the arrangement above it even if its internal passage is short.


Put the purchasing description beside the drawing
A useful requisition identifies both mating part numbers, expected service envelope, material/temperature requirements, applicable product specification and traceability, working pressure by region, seal kit, hardware and certification. Carry out receipt checks against that requisition. An apparent mismatch is a reason to reopen the interface review before accepting a substitute part.
Screen the service class independently of flange fit
Consider two offered adapters with identical bolt pattern, ring designation and rated working pressure. The well-specific purchase specification also requires a particular temperature range and material suitability for the produced fluid. A bid that identifies the flange ends but supplies no traceable body, seal and bolting data leaves those requirements unresolved. A drawing that proves mechanical fit cannot supply the missing material evidence.
For each offered part, match the serial or part number to the controlled drawing, temperature designation, materials and service restrictions, applicable product specification level and the required qualification records. Check which requirements apply to the whole assembly and which to individual end connections. Keep the common-bore pressure limitation on the same review sheet. Do not infer a sour-service rating or a valid pressure–temperature envelope from a pressure stamp alone.
Field comparison
| Attribute | Check lower end | Check upper end |
|---|---|---|
| Connection and seal | Face/groove, ring and material | Face/groove, ring and material |
| Pressure | What volume reaches this face? | Same volume or qualified separate region? |
| Mechanical fit | Mating part, fasteners, access | Mating part, fasteners, access |
| Tool passage | Minimum ID through lower region | Minimum ID through upper region |

What to record in the field
| Check or record | Job-specific entry |
|---|---|
| Sketch the pressure path with the well in each planned operating condition. | |
| Record both connection designations, gasket numbers, minimum ID and certified service envelope. | |
| List which seals and tubulars must be installed for any differentiated pressure rating. |
Additional technical figures (5)





Questions from the field
Can a high-rated upper flange upgrade the lower equipment?
No. In a common pressure volume the lower-rated component still limits the assembly. Qualified separated pressure regions require the specific engineered crossover.
Can I identify the gasket from the nominal bore alone?
No. Bore, pressure class, groove type and exact connection designation all matter. Confirm the named gasket on each mating face.
Why check overall height as well as face dimensions?
Stack height affects clearances, access and applied bending loads. An adapter must fit the working arrangement as well as its neighboring faces.

Technical references
Well Intervention Pressure Control, Well Construction Principles. PDF pp. 84–85, ring gaskets and type 6B/6BX flange connections.
API Specification 6A, specification for wellhead and tree equipment. 21st edition, §§14.2.1 and 14.8, ring-gasket families and crossover-connector designs. Use the edition specified for the equipment.
Mike Speer, Introduction to Wellhead Systems, SPE Petroleum Engineering Handbook, Volume II. Chapter 8, PDF pp. 350–354, sections 8.1.1–8.1.3 and Figs. 8.1–8.8.