Wireline Grease Injection Control Head: Flow Tubes, Cable Fit and Seal Evidence

A wireline grease injection control head contains well pressure around moving armored cable by pumping viscous grease into closely fitting flow tubes. The extended annular restriction lets the grease support a pressure gradient. Cable fit matters because a stranded exterior presents both an irregular outer surface and possible leak paths between strands.

Follow the sealing medium, not just the cable

The head sits at the top of the lubricator package. A designated injection connection supplies grease to the flow-tube assembly; a check valve can protect the supply side from reverse flow. Cable passes through the tube stack and exits the head. Depending on the design, excess grease is removed or collected above the sealing section. The injection, return and hydraulic-control lines serve different functions and belong on separate labels on the rig-up drawing.

In the NOV Enviro design, the hydraulic pack-off is intended to seal on a stationary wireline, and the wiper strips excess grease from moving cable. These components should be described by function. A clean cable leaving the wiper does not prove integrity of the underlying dynamic seal. Conversely, grease at a designed return is different from uncontained well fluid.

Inside the grease injection head. Injected grease occupies the narrow annulus around a moving armored cable.
Conceptual cross-section separates the flow tubes, stationary pack-off and wiper. Actual ports and tube count depend on the assembly.

Calculate what the clearance entry means

Suppose a measured cable OD is 0.312 in and a measured flow-tube bore is 0.317 in. The diametral clearance is bore minus cable OD, or 0.005 in. With perfectly concentric round parts, the radial gap would be half this, or 0.0025 in. Reporting only “0.005 clearance” without the basis invites a twofold error.

Those figures are an arithmetic example, not an acceptance criterion. Obtain the approved tube-to-cable range and measurement method for the specific tool and service. Record the actual diameter variation and cable condition. A single catalogue cable size does not capture wear, change in armor condition or differences along the length of the line.

For the cable and toolstring context, see wireline-conveyed perforating. Use the well integrity guide when tracing the envelope around the pressure-control head.

Flow-tube clearance in cross-section. A concentric sketch distinguishes the flow tube, grease-filled passage and cable.
A concentric sketch distinguishes the flow tube, grease-filled passage and cable.

Why a pump gauge alone cannot confirm the seal

Different pressures can exist at the pump, within the supply hose, at the injection point and at the wellhead. Grease characteristic, temperature, flow, tube geometry, injection arrangement and movement of the cable affect the pressure distribution. An indication at a remote pump identifies only the pressure at that instrument at that time.

If grease consumption changes with similar wellhead pressure, compare like operating states. Record cable speed and direction, grease temperature, measured flow-tube ID and cable OD, supply and return indications, and any visible fluid at the head. Keep the drum and tube serial numbers alongside those measurements so the clearances can be reconstructed. An unnoticed change from a cold start to sustained movement can defeat comparison of two isolated gauge readings. Treat loss of containment according to the approved well-control response; a diagnosis from the readings alone cannot authorize continued operation.

Calculate diametral and radial gaps. Arithmetic example only. The OEM defines the acceptable range for a given assembly.
Arithmetic example only. The OEM defines the acceptable range for a given assembly.
Wireline grease head laid horizontally on trestles
The grease head is laid out at ground level for a clear view of its length and connections. Photo by Schwindj (CC BY-SA 4.0).

What a replacement tube or cable changes

A different cable construction can require a different line-size kit, flow tubes, wiper and static pack-off. Verify connection compatibility and the actual pressure and temperature envelope of the complete stack. Match grease to the approved service and environmental conditions. The manufacturer defines the permissible combination of tubes and injection points for the anticipated well pressure and fluid.

Keep the setup record with the drum identification. When a second crew brings a replacement drum of identical nominal OD, it should be able to identify which measurements, certificates and acceptance checks depend on that specific cable. This makes a configuration change visible before the head is credited as available.

Quantify what two thousandths of bore wear changes

For ideal round sections, passage area is π/4 × (tube ID² − cable OD²). With the example dimensions it is approximately 0.00247 in². If the measured bore increases to 0.319 in while the cable remains 0.312 in, the area becomes about 0.00347 in², roughly 40% larger. The cable nominal size on the drum label has not changed.

This calculation compares geometry. It cannot predict the grease delivery pressure, leak rate or number of tubes required. Temperature, grease properties, actual cable construction, wear and the length of the effective restriction matter. Compare measured parts and the job conditions with the supplier’s approved combination, then interpret pump and head readings at their actual measurement points.

Field comparison

ElementIts jobEvidence to record
Flow tube stackRestrict flow around moving cable with injected greaseTube bore, cable measurements and approved size combination
Stationary pack-offSeal around stationary cable when designed for itModel, size kit, operating condition and verification
Line wiperRemove residual grease from cableCorrect element and collection condition
Injection manifold and check valveDeliver grease and control reverse flowConnection identification, orientation and test record
Wireline pressure-control pack-off photographed off the well
This separate pack-off illustrates the distinction between a mechanical seal and the grease-head assembly. Photo by Schwindj (CC BY-SA 3.0).

What to record in the field

Check or recordJob-specific entry
Cable drum, nominal OD and measured OD range
Tube bore, diametral clearance and OEM acceptance basis
Grease grade, temperature, monitoring locations and returns route
Static pack-off/wiper identification and verified barrier drawing revision
Additional technical figures (5)
What the two gauge locations mean. State the measuring location; supply and injection pressure can differ.
State the measuring location; supply and injection pressure can differ.
Distinguish the three fluid paths. Label the lines by function on the actual package drawing.
Label the lines by function on the actual package drawing.
Why a replacement drum changes the review. Identical nominal diameters do not verify the replacement cable and fitted parts.
Identical nominal diameters do not verify the replacement cable and fitted parts.
Interpret what appears at the head. Identify the actual source and expected destination before assigning a cause.
Identify the actual source and expected destination before assigning a cause.
Make grease-use trends comparable. Collect the variables associated with each observation before drawing a conclusion.
Collect the variables associated with each observation before drawing a conclusion.

Questions from the field

Can the wiper substitute for the moving grease seal?

A wiper removes surplus grease. Its cleaning performance does not establish well-pressure containment.

What is the difference between diametral and radial clearance?

Diametral clearance is the bore minus cable diameter. In an ideal concentric geometry radial clearance is half that value.

Can a universal tube count be set from well pressure?

Use the manufacturer’s engineered selection for the actual cable, head, grease and service. Two assemblies at the same pressure may require different configurations.

Offshore logging cabin beside a reel of wireline cable
The cable reel and logging cabin are on the atmospheric side of the pressure-control equipment. Photo by Ciacho5 (CC BY-SA 3.0).

Technical references

Well Intervention Pressure Control, training handout. PDF pp. 188–191, braided rig-up and grease seal.

NOV, Enviro Wireline Grease Injection Control Head. Flowtube, stationary pack-off and wiper descriptions.

Leave a Comment