Casing Leak Detection Methods and What Each Result Proves

An annulus that gains pressure is a symptom. Before ordering a casing log, identify which two spaces appear to communicate, whether fluid moved under the recorded conditions, and which depth interval matters to a repair decision. A test that detects communication, a log that detects moving fluid and an inspection that measures steel answer three different questions.

Start with a pressure history you can interpret

Plot the pressures of the tubing and relevant annuli on the same time axis. Add well state, production or injection changes, temperatures, fluid additions and the history of any approved tests. Check that instruments refer to the intended ports, agree in units and have a traceable range and calibration. A trapped fluid that heats up can raise pressure. A leaking surface isolation component can also make one monitoring point appear to communicate with another.

An approved isolation or communication test can narrow the affected boundary. A response seen at surface usually identifies a pair of connected volumes more readily than it identifies the actual hole depth. The volume of compressible fluid, temperature drift and the initial differential all influence the response. Preserve those conditions for the person interpreting the record.

Separate the three leak questions. No single measurement establishes communication, exact flow depth and remaining pipe wall.
No single measurement establishes communication, exact flow depth and remaining pipe wall.

Use flow-sensitive logs to localize the anomaly

A noise log listens for energy generated by moving fluid. High-resolution temperature can show a localized departure from the surrounding thermal profile. Look for repeatable, depth-correlated changes under a known operating condition. Flow behind pipe, an intended perforation, downhole hardware and normal flow restrictions can also create signatures. Record their known depths before assigning a leak location.

A quiet interval offers limited reassurance if the pressure differential that drove the suspected leak disappeared during the survey. The logging engineer may compare approved operating states or repeat a pass. Background noise and the thermal history of circulation influence interpretation. Do not turn a single isolated amplitude or temperature change into an exact leak rate.

The tubing versus packer leak diagnosis helps identify alternative paths for annulus pressure. A multifinger caliper log adds geometry evidence where casing is accessible.

What an internal caliper can miss. External wall loss may leave the inner profile unchanged even as the remaining steel becomes thinner.
External wall loss may leave the inner profile unchanged even as the remaining steel becomes thinner.

Use metal inspection to characterize the string

A multifinger caliper maps the accessible internal surface. It can identify internal pits, grooves and deformation at its available coverage and resolution. External metal loss can leave the inside diameter nearly unchanged. For example, the SLB USI ultrasonic imager transmits a 200–700 kHz pulse. The casing resonance frequency gives a wall-thickness estimate. Decay of the returning signal is used to assess acoustic coupling to material outside the casing. A thin-wall measurement and a poor-bond indication at the same depth can therefore come from different features of the same waveform. Evidence of flow under a known pressure differential is still needed to tie either observation to an active leak.

Consider a survey reporting concentrated metal loss at 2,410 m MD, while repeated noise and temperature changes occur near 2,460 m MD. Compare the depth references, collar correlation and uncertainty first. If the 50 m gap persists, keep two findings. The first is an integrity concern and the second is evidence of local flow. Selecting a repair at one solely because it lies close to the other risks treating the wrong pathway.

Two anomalies separated by 50 metres. Depth-correlate the metal indication and flow anomaly before assigning one repair target.
Depth-correlate the metal indication and flow anomaly before assigning one repair target.
Gauges installed on a surface wellhead
Surface gauges can show a pressure response but do not locate the downhole flow path. Photo by Joshua Doubek (CC BY-SA 4.0).

Write the intervention decision in measurable terms

The decision record should name the suspected source and receiving volume, the evidence for active flow, the best depth interval, the condition of the candidate string, and competing explanations. A post-repair verification plan should test the originally observed communication under defined conditions. A clean internal profile alone cannot demonstrate that communication has ceased.

Use depth intervals and a repeatable pressure state to rank leak candidates

If the metal-loss feature at 2,410 m MD has a ±3 m depth uncertainty and the flow-sensitive response at 2,460 m MD has ±5 m, their intervals are 2,407–2,413 m and 2,455–2,465 m. Even their nearest limits are 42 m apart. Once both logs share a reference and the stated bounds are defensible, simple depth-pick uncertainty does not explain the separation.

At each candidate depth, record the available pressure contrast and whether the well was flowing, shut in or changing state. A noise or temperature survey can lose its signal when the driving differential disappears. A flowing channel behind pipe can also carry fluid away from its point of entry. Document which measurement identifies communication, which locates movement and which establishes metal condition before specifying the repair interval.

Field comparison

MethodQuestion answeredImportant blind spot
Pressure communication testDo the isolated volumes respond together?Usually weak depth resolution
Noise and temperature loggingWhere is there evidence consistent with fluid movement?Flow may cease under survey conditions
Multifinger caliperWhere has accessible internal geometry changed?Outer-wall loss can be invisible
Ultrasonic or EM inspectionWhere does measured wall or metal response change?A flaw does not establish active flow
Surface equipment for a dual completion in British Columbia
The dual-completion wellhead illustrates why the pressure record must identify the exact path observed. Photo by Dexcel at en.wikipedia (Public domain).

What to record in the field

Check or recordJob-specific entry
Sketch the tubing and A/B annuli with named pressure taps and possible flow paths.
Record time, depth datum, well state, differential and tool resolution for each result.
Keep active-flow evidence and structural-damage evidence in separate columns until they correlate.
Additional technical figures (5)
Compare survey sensitivity. Each method responds to a different physical property.
Each method responds to a different physical property.
Why compare flowing and quiet conditions?. Synthetic illustration only. Repeated local changes under a driving differential help focus interpretation.
Synthetic illustration only. Repeated local changes under a driving differential help focus interpretation.
Map each pressure tap to its volume. Identify tubing, A annulus and outer monitored annulus on the actual completion schematic; ports shown schematically.
Identify tubing, A annulus and outer monitored annulus on the actual completion schematic; ports shown schematically.
What a negative observation establishes. Record differential, time and sensitivity before interpreting an absence of flow.
Record differential, time and sensitivity before interpreting an absence of flow.
Correlate the depths before committing to repair. Check independent data at a common datum; retain distinct findings if uncertainty cannot bridge the difference.
Check independent data at a common datum; retain distinct findings if uncertainty cannot bridge the difference.

Questions from the field

Can a temperature log alone identify the leaking string?

A thermal anomaly may locate a flow-related interval. Completion geometry, other logs and the operating state are needed to assign the pathway to a string.

Does an enlarged ID prove a through-wall hole?

No. It shows a change to the internal profile. Remaining wall and communication require additional evidence.

What does a negative leak test establish?

It constrains communication across the tested boundary at the differential, duration, sensitivity and temperature conditions actually achieved.

Several wireline logging tools stored side by side on a rack
Downhole instrument dimensions and accessible bore matter when planning a diagnostic survey. Photo by Joshua Doubek (CC BY-SA 4.0).

Technical references

Cased Hole Evaluation Guidelines, EP 93-1585. PDF p. 59, section 3.7.3, noise logging.

Schlumberger, Cased Hole Log Interpretation Principles/Applications. PDF pp. 111–113, corrosion evaluation of casing and tubing.

SLB high-definition leak detection. Well integrity evaluation and casing inspection methods.

BSEE technical review of sustained casing pressure.