When two suppliers quote API 200 screens, compare their tested D100, conductance and nonblanked area, then price the service each panel delivers. The lowest unit price can lose its advantage through short life or more liquid discharged with cuttings. A side-by-side bid sheet keeps the label values separate from the performance the rig still has to establish.
Read the separation number first
A screen supplier offers two API 200 panels for the same deck. The mud engineer wants finer separation and the driller wants to stop losing whole mud over the end. The API number alone cannot settle that discussion. The designation groups the tested separation result into a size range. It does not report the opening in every layer of cloth or the percentage of actual drilled solids that will leave the active system.
D100 is established by comparing separation of a specified test material with reference sieves under controlled conditions. Write the published value in micrometres alongside the designation. Avoid converting a mesh count directly into an API designation. Wire diameter, weave and the construction of a multilayer panel change what the assembled screen does. A hydrocyclone D50, by comparison, describes a split between two streams for one size class.


Where the liquid can pass
Conductance is reported in kD/mm. It characterizes the screen medium on a unit-area basis. Nonblanked area excludes areas closed to flow by the design of the panel. A supporting frame can give two panels with comparable external dimensions different effective areas. Record the area of one panel and the number actually installed before comparing deck configurations.

| Hypothetical screen label | Panel A | Panel B |
|---|---|---|
| API designation | API 200 | API 200 |
| Reported D100 | 77 µm | 79 µm |
| Conductance | 0.80 kD/mm | 1.00 kD/mm |
| Nonblanked area | 0.50 m² | 0.40 m² |
Multiplying the last two rows gives the same numerical product for these examples. That arithmetic illustrates a tradeoff between area and conductance. It gives no rated flow in barrels per minute. It leaves out the properties of the circulating fluid, the solids feed, vibration, blinding and how evenly the flow reaches the screen. Likewise, the small difference in the illustrative D100 values does not establish a useful difference in drilled-solids removal on the rig.

Compare panels during a representative interval
Start with the reason for the change. If whole mud is escaping, record where it leaves and whether every shaker sees the same problem. One deck flooding beside a lightly loaded deck points toward feed distribution. A marked change with one interval of sticky cuttings raises a different question about blinding. A tear can pass oversize solids while the deck still appears to handle fluid comfortably.

For a field comparison, record flow rate, mud density and rheology, formation interval, approximate cuttings loading, deck settings and screen condition. Note any bypass and the time in service of the panels. If flow or lithology changes at the screen change, retain both observations and treat the result as an interrupted trial. A photograph of the fluid endpoint is more informative when it identifies the deck and operating condition.

Make the purchasing decision traceable
A defensible recommendation names the exact panel, the problem observed and the measure that improved. For example, two panels may make equally dry-looking discharge, while one requires more changeouts during the interval. Record service life separately from fluid loss and solids quality. Where the decision concerns liquid losses, a representative wet-discard sample gives a firmer comparison than appearance alone.

Put the two bids on an operating-hour basis
Suppose A costs $240 and lasts 24 operating hours, while B costs $300 and lasts 40 hours in matched service. The panel cost is $10.00/h for A and $7.50/h for B. This comparison assumes equal panel counts. With four panels per deck the figures become $40/h and $30/h. If a changeout discards reusable sections or consumes rig time, list those costs separately and identify how they were measured.

The $10/h difference per four-panel deck is a useful break-even amount. If verified extra fluid losses on B cost more than $10/h, B loses its purchase-cost advantage under these assumptions. Until fluid loss is measured, keep the figure as the cost difference the field trial needs to resolve.
See the label examples and field-trial checks



Field or laboratory record
Download the editable screen bid and trial record (TXT).
Frequently asked questions
Does a larger API number guarantee a higher flow capacity?
No. It moves the separation designation toward finer sizes. Capacity depends on screen construction, available area, drilling-fluid properties and how the shaker is loaded.
Can I use the screen label to predict all solids larger than D100 will be removed at the rig?
The label describes the separation test. Bypass, damaged panels, particle shape and the condition of the working deck affect field separation. Check the return stream if the decision depends on the field result.
What should go on the rig report?
Record panel identity, API designation, D100, conductance, nonblanked area and number of panels. Couple those values with the service interval, operating conditions and the measure you used to judge the change.
Further reading and technical references
For screen construction and the API classification table, see Shaker Screen Design, Specifications & Good Tips. For the deck variables to hold constant during a field trial, see Shale Shaker Design & Performance.
ASME Shale Shaker Committee. Drilling Fluids Processing Handbook. Gulf Professional Publishing, 2005. Printed pp. 167–174 (PDF pp. 194–201), §7.10.2. Printed pp. 118, 147 (PDF pp. 145, 174).