How to Compare Two API 200 Shaker Screen Bids

When two suppliers quote API 200 screens, compare their tested D100, conductance and nonblanked area, then price the service each panel delivers. The lowest unit price can lose its advantage through short life or more liquid discharged with cuttings. A side-by-side bid sheet keeps the label values separate from the performance the rig still has to establish.

Read the separation number first

A screen supplier offers two API 200 panels for the same deck. The mud engineer wants finer separation and the driller wants to stop losing whole mud over the end. The API number alone cannot settle that discussion. The designation groups the tested separation result into a size range. It does not report the opening in every layer of cloth or the percentage of actual drilled solids that will leave the active system.

D100 is established by comparing separation of a specified test material with reference sieves under controlled conditions. Write the published value in micrometres alongside the designation. Avoid converting a mesh count directly into an API designation. Wire diameter, weave and the construction of a multilayer panel change what the assembled screen does. A hydrocyclone D50, by comparison, describes a split between two streams for one size class.

Screen tag table separating API 200 and 77 micrometres from conductance and nonblanked area.
An API screen designation groups the tested D100 separation. Conductance describes hydraulic response per area, and nonblanked area describes available surface. The values shown are hypothetical.
A shaker screen and connected surface pipework on a land drilling rig.
A shale-shaker screen installed on a land drilling rig. The installed assembly puts the laboratory screen designation in context. Photo: Prodigys3. Source. CC BY 3.0. Source photograph converted to WebP, resized proportionally where needed, with original framing retained.

Where the liquid can pass

Conductance is reported in kD/mm. It characterizes the screen medium on a unit-area basis. Nonblanked area excludes areas closed to flow by the design of the panel. A supporting frame can give two panels with comparable external dimensions different effective areas. Record the area of one panel and the number actually installed before comparing deck configurations.

Three fluid arrows pass through a clean panel from upstream to downstream in a controlled comparison.
At comparable test conditions, conductance expresses the screen’s ease of fluid transmission per unit area. Actual mud throughput also responds to the fluid and loading on the shaker.
Hypothetical screen labelPanel APanel B
API designationAPI 200API 200
Reported D10077 µm79 µm
Conductance0.80 kD/mm1.00 kD/mm
Nonblanked area0.50 m²0.40 m²

Multiplying the last two rows gives the same numerical product for these examples. That arithmetic illustrates a tradeoff between area and conductance. It gives no rated flow in barrels per minute. It leaves out the properties of the circulating fluid, the solids feed, vibration, blinding and how evenly the flow reaches the screen. Likewise, the small difference in the illustrative D100 values does not establish a useful difference in drilled-solids removal on the rig.

Side-by-side class, D100, conductance and available area of hypothetical shaker panels A and B.
The two example panels have the same class. The conductance advantage for B is paired with less nonblanked area. Values are illustrative.

Compare panels during a representative interval

Start with the reason for the change. If whole mud is escaping, record where it leaves and whether every shaker sees the same problem. One deck flooding beside a lightly loaded deck points toward feed distribution. A marked change with one interval of sticky cuttings raises a different question about blinding. A tear can pass oversize solids while the deck still appears to handle fluid comfortably.

Three round metal laboratory sieves, arranged from coarser to finer openings.
From left, the three laboratory sieves have nominal openings of 1,700, 500 and 250 µm. Reference sieves give a size comparison a physical basis. Photo: © BMK (de.wikipedia.org). Source. CC BY-SA 3.0. Converted to WebP. Orientation preserved. Proportionally resized to a maximum of 1,600 pixels without enlargement. Original framing and labels retained.

For a field comparison, record flow rate, mud density and rheology, formation interval, approximate cuttings loading, deck settings and screen condition. Note any bypass and the time in service of the panels. If flow or lithology changes at the screen change, retain both observations and treat the result as an interrupted trial. A photograph of the fluid endpoint is more informative when it identifies the deck and operating condition.

Conductance times surface area equals 0.40 for both panels and yields a relative product of one.
The products of conductance and nonblanked area match in this example. The product is a relative clean-screen comparison; it cannot supply a rig flow rating.

Make the purchasing decision traceable

A defensible recommendation names the exact panel, the problem observed and the measure that improved. For example, two panels may make equally dry-looking discharge, while one requires more changeouts during the interval. Record service life separately from fluid loss and solids quality. Where the decision concerns liquid losses, a representative wet-discard sample gives a firmer comparison than appearance alone.

A red dual-deck shale shaker viewed from the discharge end.
The two decks on this shale shaker provide separate screen positions. A panel designation belongs to the panel fitted in the position being reported. Photo: Iamorr. Source. CC BY-SA 4.0. Converted to WebP. Orientation preserved. Proportionally resized to a maximum of 1,600 pixels without enlargement. Original framing and labels retained.

Put the two bids on an operating-hour basis

Suppose A costs $240 and lasts 24 operating hours, while B costs $300 and lasts 40 hours in matched service. The panel cost is $10.00/h for A and $7.50/h for B. This comparison assumes equal panel counts. With four panels per deck the figures become $40/h and $30/h. If a changeout discards reusable sections or consumes rig time, list those costs separately and identify how they were measured.

Field-trial record linking panel identification to the feed window, observed response and interpretation.
A field comparison should couple the measured label descriptors with feed conditions and observations from a defined window. Where conditions changed, preserve both records.

The $10/h difference per four-panel deck is a useful break-even amount. If verified extra fluid losses on B cost more than $10/h, B loses its purchase-cost advantage under these assumptions. Until fluid loss is measured, keep the figure as the cost difference the field trial needs to resolve.

See the label examples and field-trial checks
API 200 range with open lower endpoint at 69 micrometres, closed upper endpoint at 82.5, and two examples at 77 and 79.
The API 200 interval is greater than 69.0 µm through 82.5 µm. The two example D100 values both lie inside this band.
Two same-size screen footprints have different support bands, showing different exposed areas.
Two conceptual flat panels occupy equal footprints. Different support layouts mask different amounts of surface. Proportions are illustrative.
Three groups of field variables affecting a screen trial: incoming mud, installed screen and shaker deck.
Feed rate and solids loading influence how much material reaches a panel. Screen condition and shaker settings affect the surface available to handle it.

Field or laboratory record

Download the editable screen bid and trial record (TXT).

Frequently asked questions

Does a larger API number guarantee a higher flow capacity?

No. It moves the separation designation toward finer sizes. Capacity depends on screen construction, available area, drilling-fluid properties and how the shaker is loaded.

Can I use the screen label to predict all solids larger than D100 will be removed at the rig?

The label describes the separation test. Bypass, damaged panels, particle shape and the condition of the working deck affect field separation. Check the return stream if the decision depends on the field result.

What should go on the rig report?

Record panel identity, API designation, D100, conductance, nonblanked area and number of panels. Couple those values with the service interval, operating conditions and the measure you used to judge the change.

Further reading and technical references

For screen construction and the API classification table, see Shaker Screen Design, Specifications & Good Tips. For the deck variables to hold constant during a field trial, see Shale Shaker Design & Performance.

ASME Shale Shaker Committee. Drilling Fluids Processing Handbook. Gulf Professional Publishing, 2005. Printed pp. 167–174 (PDF pp. 194–201), §7.10.2. Printed pp. 118, 147 (PDF pp. 145, 174).

Leave a Comment