On a cumulative undersize curve, D10, D50 and D90 are the diameters below which 10%, 50% and 90% of the measured population fall on the reported basis. For a volume distribution, write Dv10, Dv50 and Dv90. These numbers describe the bridging material. They do not directly specify the size of formation pore throats the formulated fluid will seal.
Pick the correct curve before reading the numbers
Look for “percent passing” or “cumulative undersize” on the vertical axis. A retained or oversize plot runs the other way. Check whether the data are by volume, mass or count and whether the size axis is logarithmic. Sieve measurements commonly report mass fractions. A laser-sizing method can report a volume distribution using an optical particle model. Particle shape, dispersion and the treatment of agglomerates can change the reported result.

For an illustrative volume distribution with Dv10 = 12 µm, Dv50 = 35 µm and Dv90 = 80 µm, half the measured particle volume is below 35 µm. Approximately 10% is above 80 µm. Dv90 is not the largest particle. A small number of coarse particles can account for a substantial share of total particle volume, so a count-based median and a volume-based median can differ strongly.

Compare the tails as well as the median
A useful width descriptor is (Dv90 − Dv10)/Dv50. For those three example values it is (80 − 12)/35 ≈ 1.94. The ratio is dimensionless. It describes the spread between selected percentiles relative to the median. It cannot reconstruct the full curve or identify a gap in an intermediate size band. Request the cumulative table when selecting between grades.

| Review question | Evidence to request |
|---|---|
| Do both lots really have similar medians? | Equivalent test method, dispersion procedure and reporting basis. |
| How much coarse material is present? | Cumulative passing at an agreed coarse threshold, with a check on oversize. |
| Is the fine fraction stable between lots? | Cumulative passing at a fine threshold the instrument resolves reliably. |
| Does the blend seal the intended medium? | Matched fluid formulation and filtration evidence on a representative medium. |

Blend distributions at common size thresholds
Suppose at 40 µm, 80% of fine grade A and 20% of coarse grade B are below the threshold on the same volume basis. A blend containing 60% A and 40% B by particle volume has cumulative passing of 0.60 × 0.80 + 0.40 × 0.20 = 56% at 40 µm. Repeat the calculation at common diameters to construct the blend curve. Then read the blend percentiles from that curve.

Averaging the D50 values of the two stocks does not generally give the D50 of the blend. A percentile is a location on a distribution. The fractions are additive at a given diameter; their percentile diameters are not. Where grades have different particle densities, convert dry mass proportions to particle volume before applying volume-based curves. A mass-weighted sieve calculation instead uses mass fractions throughout.

Check what reaches the cake
The grade delivered in the sack is not necessarily the distribution circulating across the reservoir interval. Shear, solids-control losses, dilution, new drilled solids and sampling location can all change the measured population. Label a PSD measured on neat carbonate separately from a PSD measured on whole circulating mud. The latter includes material with different chemistry and removability.


Select candidate blends against evidence about the pore system and formation, then compare formulated fluids under representative filtration conditions. Record spurt, subsequent filtration, cake character and cleanup evidence as appropriate. A blend with a visually appealing size curve still has to demonstrate sealing and removability in its intended system.
Compare number, volume and blend distributions



Field or laboratory record
Download the editable bridging blend psd record (TXT).
Frequently asked questions
Is a bridging D50 the same as a separator D50?
A product D50 is a percentile of the material distribution. A hydrocyclone D50 identifies a size class split equally between two outlets under a stated test.
Can a supplier’s “medium” grade be treated as a fixed micron size?
Grade names alone are insufficient. Ask for the measured curve, lot variability, units, basis and test method.
Which numbers belong on a purchase comparison?
Include D10, D50, D90, measurement basis, selected passing fractions, lot identity and performance of the formulated fluid in a relevant test.
Further reading and technical references
For the distinction between reservoir drill-in bridging and lost-circulation applications, see Bridging Materials Theory & Mechanisms. For the consequences of solids invasion, see Formation Damage: Causes, Diagnosis & Prevention.
Baker Hughes INTEQ. Drill-in Fluid Systems: Reference Manual, 750-500-109, Rev. A, June 1999. Printed pp. 1-14–1-15, 2-4 (PDF pp. 21–22, 33).
R. Caenn, H. C. H. Darley and G. R. Gray. Composition and Properties of Drilling and Completion Fluids, 7th ed. Gulf Professional Publishing, 2017. Printed pp. 73, 260–261, 509 (PDF pp. 78, 264–265, 511).
ASME Shale Shaker Committee. Drilling Fluids Processing Handbook. Gulf Professional Publishing, 2005. Printed p. 175 (PDF p. 202), §7.10.