Dynamic Filtration Testing: Comparing Static and Moving-Fluid Tests

A dynamic filtration test measures filtration while drilling fluid moves relative to the exposed cake surface. The movement can remove deposited material, so the barrier develops differently from a cake allowed to grow without that surface erosion. The useful result includes the fluid-loss history, the imposed movement, the medium and the recovered cake observations. [1, pp. 68, 264–265]

This article concentrates on interpreting moving-fluid tests. The existing API filter press procedure and HPHT filter press procedure cover their respective static evaluations. A dynamic result adds a different piece of evidence; its meaning depends on how the laboratory represented flow at the cake.

What makes a dynamic filtration test different?

Two directions of movement matter. The mud moves along the cake surface, applying hydrodynamic shear. Filtrate moves through the cake and the porous medium because of a pressure difference. Calling a test dynamic refers to the first movement. Filtrate also moves during a static filtration test, so “static” does not mean that no liquid leaves the cell. [1, pp. 68, 264–265]

Keep these movements separate when reading an equipment drawing. A circulating loop, a rotating cylinder and an internal rotating element can create different flow fields. Their shared purpose is to expose the developing barrier to movement, but the resulting surface shear is not automatically equivalent. Caenn and colleagues identify the shear at the cake surface as particularly important to the interpretation. [1, p. 68]

The practical question is therefore specific: how does this fluid form and maintain a barrier on this medium under the stated movement and pressure conditions?

Dynamic filtration test cross-section showing mud movement along the cake and filtrate passing through it.
Mud movement acts along the exposed cake; filtrate passes through the barrier. The section is conceptual and not an apparatus assembly drawing.
Dynamic filtration test research setup with laboratory apparatus, sleeve-type core holder and the original flow schematic.
Published core-invasion setup: (a) laboratory apparatus, (b) sleeve-type core holder and (c) the original pressure-flow schematic. The complete figure shows one dynamic core-testing arrangement. Photo: Zhujun Li, Xianjin Zeng, Qing Huang, Kaiyu Yang, Tao Zhang, Pengfei Li, Xiangke Shi, Ting Li, Huaqiao Yang and Zhiyuan Wang. Permeability Characterization of Drilling Fluid Invasion Zone in Ultra-High-Temperature and High-Pressure Gas Wells. Figure 1. Processes 2026, 14(6), 960. Published by MDPI. DOI: 10.3390/pr14060960. © 2026 the authors. CC BY 4.0. EXIF orientation normalized where present; resized proportionally to a maximum of 1600 pixels without enlargement; converted to WebP. No retouching or added labels. The publisher’s two source image files for Figure 1 were joined vertically in original panel order, retaining (a), (b) and (c). No cropping or panel removal.

Static and dynamic cakes develop under different balances

In idealized static filtration, retained solids continue adding to the cake as filtrate passes through it. The growing barrier increases resistance and the rate of accumulation slows. Under dynamic conditions, fluid movement can remove material from the exposed surface while new solids are deposited. A steady cake thickness becomes possible when these processes balance. [1, pp. 264–265]

The distinction explains why a low static volume cannot automatically establish a low moving-fluid rate. Static testing observes one route to barrier development; movement changes that route. The AVA manual discusses examples in which fluids with similar static results had different dynamic responses. Those historical examples demonstrate a limitation of substitution, rather than a conversion factor between the two tests. [2, pp. 185–186]

FeatureStatic comparisonDynamic comparison
Movement along the cakeNo imposed continuous surface movementDefined movement acts on the surface
Cake developmentContinued deposition can increase thicknessDeposition competes with erosion
Important outputCollected volume and cake under stated conditionsTime-dependent loss, movement conditions and cake
Interpretation limitDoes not reproduce surface erosionRepresents the selected geometry and history
Static and dynamic filtration test comparison showing continued cake growth and competing deposition and erosion.
The paired sections isolate the movement difference. Cake dimensions are illustrative; the diagram does not predict a universal thickness or loss ratio.

Constant cake thickness does not prove a constant filtration rate

Deposition and erosion explain the thickness balance, but thickness is only one part of the barrier. Its permeability can continue changing through compaction or rearrangement of the deposited particles. Caenn describes a stage in which thickness is approximately constant while filtration rate continues declining. Only later may both settle into a relatively steady response. [1, p. 265]

That distinction matters when someone labels a short observation “equilibrium.” A recovered cake measurement is an end-point observation. It does not reveal whether permeability was constant during the preceding collection interval. Similarly, a nearly straight portion of a volume-time plot supports a relatively steady rate over that portion, without proving that every cake property has stabilized.

For a dynamic filtration test, state the observation behind the conclusion: the interval used to calculate rate, the stability of the operating conditions, and any evidence about the cake. Avoid treating “thin cake,” “stable cake” and “low permeability” as interchangeable descriptions. The broader bridging-material mechanisms guide provides related context on establishing a barrier.

Dynamic filtration test stages separating cake growth, changing permeability and later steady response.
A thickness plateau alone does not prove steady filtration. The stages describe a possible progression without assigning universal times or numeric rates.
Five HTHP static-filtration cakes showing different appearances in an oil-based drilling-fluid additive study.
HTHP static-filtration cakes from the published oil-absorbent-polymer study: (a) control and (b–e) increasing OAP concentrations. Cake appearance is one observation to record alongside filtrate volume. Photo: Hanyi Zhong, Guangcheng Shen, Peng Yang, Zhengsong Qiu, Junbin Jin and Xiaodong Xing. Mitigation of Lost Circulation in Oil-Based Drilling Fluids Using Oil Absorbent Polymers. Figure 11. Materials 2018, 11(10), 2020. Published by MDPI. DOI: 10.3390/ma11102020. © 2018 the authors. CC BY 4.0. EXIF orientation normalized where present; resized proportionally to a maximum of 1600 pixels without enlargement; converted to WebP. No retouching or added labels. No cropping; all original panels and annotations are retained.

Geometry and surface shear in a dynamic filtration test

The supplied textbook describes several ways to investigate moving-fluid filtration: circulating mud through a permeable cylinder, shearing fluid around a central medium with a rotating outer cylinder, and rotating an element inside a ceramic cylinder. These arrangements differ in how they expose the cake to flow. They should not be merged into one undocumented “dynamic” method. [1, p. 68]

Rotational speed is a machine setting. Surface shear depends on the geometry and fluid-flow relationship as well. Equal revolutions per minute in two different arrangements do not establish equal conditions at the cake. Cake growth can itself change the available flow space, which is one reason the textbook discusses the relative size of the cylinder and deposited layer.

Record the apparatus, medium position, movement mechanism and available shear characterization. Where the method reports speed rather than a calculated surface shear, retain that distinction. It is more useful to state a reproducible speed-and-geometry condition than to assign an unsupported shear-rate value. A comparison across instruments needs this information before the two numerical results can be interpreted together. [1, p. 68]

Dynamic filtration test geometry comparison of axial movement past a porous wall and rotation inside a porous cylinder.
Generic sections show why movement mechanism and geometry belong in the report. Equal rpm or bulk flow values are not equal surface-shear specifications.

Reading a dynamic filtration test volume record

A cumulative-volume record tells how much liquid has been collected by each time. Its slope tells how quickly liquid is accumulating. Caenn describes the dynamic filtration rate using the slope of volume against time. With volume in millilitres and time in minutes, an observed interval rate is q = ΔV/Δt, expressed in mL/min. [1, p. 68]

The average rate from the start, V/t, includes the earlier transient. It can therefore differ from the slope of the later part of the record. Neither value is wrong when correctly labelled; they describe different intervals. A report should identify which one it calls the dynamic rate.

If filtration areas differ, retain the raw rate and state the area before comparing an area-normalized quantity. Dividing q by area gives volume per area per time; it does not make different media or movement conditions equivalent. AVA highlights the difficulty of comparing dynamic results when reporting units and experimental conditions differ. [2, pp. 185–186]

Dynamic filtration test example: the final average hides the later rate

Consider the following invented collection record. Assume the stated test conditions remained unchanged during these readings. The figures are for teaching the calculation; they are not a recommended test duration, operating programme or acceptance limit.

Elapsed time, minCumulative volume, mLPreceding interval rate, mL/min
00Not applicable
1080.80
20130.50
30170.40
40210.40

For the last interval, q = (21 − 17)/(40 − 30) = 0.40 mL/min. The average over the whole record is 21/40 = 0.525 mL/min. Calling that whole-record average the final interval rate would overstate the latter by 31.25%.

The last two intervals have the same calculated slope. A defensible conclusion is that the observed rate was 0.40 mL/min from 20 to 40 minutes under the assumed unchanged conditions. It does not prove that the rate would remain unchanged indefinitely, or that another fluid would reach the same state in the same time. The source discusses different stages of cake development, so the time record should establish the comparison window. [1, pp. 264–265]

Hypothetical dynamic filtration test volume-time plot and interval rates of 0.80, 0.50, 0.40 and 0.40 mL per minute.
Invented data give a 0–40 minute average of 0.525 mL/min and a 20–40 minute rate of 0.40 mL/min. The selected duration is not a test prescription.

A dynamic filtration test also carries its earlier cake history

A well can alternate between circulation and static periods. A static deposit may develop on a cake previously exposed to circulation; restarting movement then acts on that existing structure. The textbook describes this sequence and experiments in which prior static exposure changed the following dynamic response. [1, p. 270]

A laboratory run beginning with a clean medium therefore asks a different question from one beginning with a predeposited cake. Both can be useful. The report needs to say which history was used, where the collection clock starts and whether an earlier volume belongs to the same record.

The same reasoning applies when movement changes during a run. Annotate the event on the time record rather than fitting one rate across unrelated stages. This preserves the difference between a response to increased surface movement and continued evolution of the original cake. The sequence diagram deliberately contains no fixed durations: the history must come from the selected programme.

For example, imagine two runs with identical settings during their final stage. One began with a clean surface; the other first developed a static deposit. A difference in final-stage loss cannot be attributed solely to the fluid formulation unless that earlier history is also considered. The additional deposit is part of the test specimen encountered by the moving fluid, not an incidental note. [1, p. 270]

Conceptual dynamic filtration test history showing a clean medium, moving-fluid cake, static deposit and restarted movement.
The starting cake and sequence affect what the next stage measures. The drawing shows no universal time scale and reproduces no source figure.

Why higher movement does not guarantee higher loss

Stronger surface action can remove cake material, but a universal “more speed means more filtrate” rule is too simple. The supplied books describe differing experimental responses, including cases in which increased annular velocity reduced dynamic filtration. Proposed explanations include selective removal and redeposition of particles, together with changes in the resulting barrier. [1, pp. 266–270] [2, p. 186]

Consequently, a speed comparison should be read as a result for the tested fluid, medium and flow regime. Do not convert one trend into a general rule for every polymer fluid or every circulating well. An apparent contradiction may also arise because two studies changed different geometries or began with different cake histories.

This is where the drilling-fluid properties overview is useful context: filtration is one part of a fluid’s behaviour. A formulation change can affect several properties, so the interpretation should remain attached to the measured conditions.

Make the comparison conditions visible

A useful dynamic filtration test report identifies both the deliberate change and the conditions needed to interpret it. The following record is an editorial synthesis of the apparatus and interpretation issues in the supplied filtration chapters. [1, pp. 68, 264–270] [2, pp. 184–186]

Report itemWhat to identify
Fluid and historySample identity, preparation, exposure and preceding cake deposition
MediumMaterial, geometry, exposed area and stated pore characterization
MovementMechanism, geometry, imposed speed or flow and available surface-shear basis
EnvironmentTemperature and the pressure conditions driving filtration
MeasurementsRaw time-volume record, event times and recovered cake observations
CalculationsSelected rate interval, units and any area normalization

If a report includes a cake deposition index, retain the method’s definition and calculation basis. The textbook identifies CDI as an instrument output, but the label alone is not enough to reconstruct every laboratory’s calculation. Do not silently substitute a final volume or a whole-test average for a named index. [1, p. 68]

Dynamic filtration test reporting infographic covering fluid history, medium, movement, environment, measurements and rate basis.
A reproducible comparison names the changed variable and preserves the conditions needed to interpret it.
Four transparent sand-bed columns showing drilling-fluid invasion depths with different fluid-loss additives.
Published sand-bed photographs compare the control fluid, OAP, asphaltic additive and modified lignite. This is a separate porous-medium invasion observation that complements filtration measurements. Photo: Hanyi Zhong, Guangcheng Shen, Peng Yang, Zhengsong Qiu, Junbin Jin and Xiaodong Xing. Mitigation of Lost Circulation in Oil-Based Drilling Fluids Using Oil Absorbent Polymers. Figure 14. Materials 2018, 11(10), 2020. Published by MDPI. DOI: 10.3390/ma11102020. © 2018 the authors. CC BY 4.0. EXIF orientation normalized where present; resized proportionally to a maximum of 1600 pixels without enlargement; converted to WebP. No retouching or added labels. No cropping; all original panels and annotations are retained.

Turn the measured difference into a bounded conclusion

A clear conclusion states what improved and where the evidence applies. For example: “Fluid B had the lower measured late-interval rate on the named medium at the specified movement, temperature and pressure conditions.” That statement can guide a formulation comparison without claiming that the same ranking applies everywhere.

Preserve the laboratory report alongside the field record; the daily mud report guide explains the wider reporting context. A laboratory rate cannot be multiplied into a reliable whole-well loss forecast without an appropriate representation of exposed area, formation properties and operating history. Likewise, filtration evidence alone does not establish cake cleanup or production performance. Those conclusions require evidence addressing those outcomes.

A comparison that changes medium, movement and fluid together can still describe those two complete test states. It is less able to isolate which individual change caused the difference. Label the comparison accordingly, and retain the original time histories so a later reviewer can examine the same interval and reporting basis.

The strongest use of a dynamic filtration test is to resolve a defined uncertainty: whether a particular fluid maintains its barrier under a stated moving-fluid challenge, and how that response changes relative to the comparison sample. [1, pp. 68, 264–270]

Dynamic filtration evidence infographic separating a laboratory rate comparison from whole-well loss, cleanup and production predictions.
State the measured difference and its conditions. Broader outcomes need evidence that addresses those outcomes.

Frequently asked questions

What does a dynamic filtration test measure?

It follows filtrate accumulation while movement acts along the developing cake. Read the collection history with the medium, surface movement and pressure-temperature conditions. A rate without those conditions is incomplete. [1, p. 68]

Is a static HPHT filter press test dynamic?

Elevated temperature and pressure do not themselves create dynamic surface exposure. The distinction is whether the method imposes movement along the cake. A static HPHT result still answers a static filtration question. [1, pp. 68, 264]

Does equal rotor speed mean equal surface shear?

No. Geometry and the flow relationship matter. State the apparatus and any valid shear calculation; do not equate identical rpm values from different arrangements automatically. [1, p. 68]

How is the dynamic filtration rate calculated?

For an observed interval, divide its volume increase by its elapsed time. Identify the interval and units. The slope of the late volume-time record can differ from total volume divided by the whole test duration. [1, p. 68]

Does a thin cake mean filtration has stabilized?

No. Thickness can become nearly constant while the cake continues changing permeability and filtration rate keeps declining. Stable thickness and stable rate are separate observations. [1, p. 265]

Can the API result predict the dynamic result?

A universal conversion is not supported by the supplied books. Fluid formulation, surface movement and earlier cake history can change the relationship. Compare actual results under their documented conditions. [1, pp. 266–270] [2, p. 186]

References

  1. Caenn, R.; Darley, H. C. H.; and Gray, G. R. Composition and Properties of Drilling and Completion Fluids. Seventh edition. Gulf Professional Publishing / Elsevier, 2017. ISBN 978-0-12-804751-4. Printed pages: 68, 264–270. PDF pages in the edition consulted: 73, 268–274.
  2. AVA Drilling Fluids & Services. Drilling Fluids Manual. Version 1, November 2004. Chapter 6, Filtration. Printed pages: 184–186. PDF pages in the edition consulted: 186–188.